<?xml version="1.0" encoding="utf-8"?>
<!-- generator="Joomla! - Open Source Content Management" -->
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
	<channel>
		<title>Utility Plants</title>
		<description><![CDATA[ Covalent Trading Group L.L.C. was born to meet the need for a new business focusing in the growing Latin-American and Caribbean market. Our capabilities comprises a vast portfolio of services, products (Chemicals) and equipment to be offered practically to all industries such as O&G Upstream and Downstream, Chemical, Petrochemical, Mining, Power, Beverage, Food, Water, Industrial, Agriculture and Pharma.]]></description>
		<link>http://covalenttrading.com</link>
		<lastBuildDate>Tue, 15 Nov 2022 01:46:35 +0000</lastBuildDate>
		<generator>Joomla! - Open Source Content Management</generator>
		<atom:link rel="self" type="application/rss+xml" href="http://covalenttrading.com/products/utility-plants?format=feed&amp;type=rss"/>
		<language>en-gb</language>
		<item>
			<title>Reverse Osmosis</title>
			<link>http://covalenttrading.com/products/utility-plants/item/94-reverse-osmosis</link>
			<guid isPermaLink="true">http://covalenttrading.com/products/utility-plants/item/94-reverse-osmosis</guid>
			<description><![CDATA[<div class="K2FeedIntroText"><p><span style="color: #ffffff;">  List Product</span></p>
</div><div class="K2FeedFullText">
<p style="text-align: justify;">CTG provides a range of additional membrane products which include flocculants for RO feed water optimization, biocides for online dosing and off line sanitization, all products are compatible with all Brand membranes. In addition, we also will supply formulated chemicals for chlorine reduction and corrosion protection in permeate supply lines.</p>
<p> </p>
<table class="responsive" style="border-collapse: collapse; border-spacing: 0; border: 1px solid #ccc;"><colgroup> <col style="width: 240px;" /> <col style="width: 394px;" /> </colgroup>
<tbody>
<tr><th class="tg-cxkv">Biocide</th><th class="tg-cxkv" style="text-align: left;">Biofilm control – on line dosing and CIPBiofilm control, off line sanitization and membrane storage</th></tr>
<tr>
<td class="tg-4eph">Flocculant</td>
<td class="tg-4eph">Membrane compatible flocculantsMembrane compatible flocculant, potable grade</td>
</tr>
<tr>
<td class="tg-031e">Flocculant, algaecide &amp; Biocide</td>
<td class="tg-031e">Flocculant with additional biocide and algaecide activity for on line use</td>
</tr>
<tr>
<td class="tg-4eph">Chlorine Scavenger</td>
<td class="tg-4eph">Removal of residual chlorine from feed water</td>
</tr>
<tr>
<td class="tg-031e">Corrosion Protector</td>
<td class="tg-031e">Corrosion inhibitor for permeate distribution systems</td>
</tr>
<tr>
<td class="tg-4eph">Cleaners</td>
<td class="tg-4eph">Successful membrane clean depends primarily on the nature of the foulant. Before electing cleaning chemicals and designing a cleaning protocol it is vitally important to correctly identify the deposit or foulant trough a RO feedwater proper lab analysis and Membrane Autopsy Service. For the most effective cleaning, and therefore reduced cleaning frequency, conditions of pH, temperature and contact time are important.</td>
</tr>
<tr>
<td class="tg-031e">Filters, Cartridges and Housings</td>
<td class="tg-031e">Filtration of: sand, scale, lime, rust, fine particles:PP Melt-Blown Filters Cartridge. (0.5-100 micron)PP Wounded Filters Cartridge. (1-100 micron) PP Melt-Blown Filters Cartridge BIG. (0.5-100 micron)PP Pleated / Melt-Blown Filters Cartridge. (0.5-100 micron)Nylon or Poliester Bag Filters Cartridge. (1-400 micron)Applications: Pharmaceutical, Food and Beverage, Process Gases and Chemicals Industries.PTFE, NYLON, PES, PP Filters Cartridge (0,05 - 2,5 absolute micron)</td>
</tr>
</tbody>
</table>
<p> </p>
<p> </p>
<p align="JUSTIFY"><span style="font-size: medium;"><span lang="en-US">Due to a different RO feed water ionic composition, it is necessary to have a proper lab analysis. As a result, different types of scale may deposit on the membranes if the correct antiscalant and/or dosage is not used. To provide optimum operating conditions for both Sea and Brackish Water RO plants, it is imperative to select the correct antiscalant. Correct product application in the RO feed water is critical to ensure the optimum plant operational performance is possible, reduce the overall costs through energy savings, reduced cleaning frequency and extend the life of the membranes.</span></span></p>
<table class="tg responsive"><colgroup> <col style="width: 246px;" /> <col style="width: 403px;" /> </colgroup>
<tbody>
<tr><th class="tg-cxkv">Antiscalants</th><th class="tg-cxkv">Main<br />Application</th></tr>
<tr>
<td class="tg-4eph" style="text-align: center;">Sea<br />Water<br />Chemicals</td>
<td class="tg-4eph">
<ul>
<li>Large systems, first and,second pass, partial recycling.,Potable use - NSF/UKDWI,</li>
<li>Small / Medium Systems. Potable use - NSF/UKDWI</li>
<li>Phosphorous free</li>
<li>High sulphate</li>
<li>
<p> Second pass (Brackish water portion of boron), high pH, high recovery</p>
</li>
</ul>
</td>
</tr>
<tr>
<td class="tg-031e" style="text-align: center;">Brackish<br />water<br />Chemicals</td>
<td class="tg-031e">
<ul>
<li>Broad spectrum, stressed water.</li>
<li>Potable use - NSF/UKDWI</li>
<li>High Calcium Sulphate Strontium Sulphate</li>
<li>High silica feed</li>
<li>High phosphate</li>
<li>Systems incorporating concentrate recycle for small systems</li>
<li>Mains feed water. Contains dechlorinator to prevent membrane oxidation</li>
<li>Broad spectrum, large municipal plant. <br />Potable use - NSF approved</li>
</ul>
</td>
</tr>
<tr>
<td class="tg-b7b8"> </td>
<td class="tg-b7b8"> </td>
</tr>
</tbody>
</table>
<p align="JUSTIFY"> </p>
<p align="JUSTIFY"> </p></div>]]></description>
			<author>mellgrafica@gmail.com (Super User)</author>
			<category>Utility Plants</category>
			<pubDate>Thu, 17 Mar 2016 00:00:00 +0000</pubDate>
		</item>
		<item>
			<title>Ion Exchange</title>
			<link>http://covalenttrading.com/products/utility-plants/item/95-ion-exchange</link>
			<guid isPermaLink="true">http://covalenttrading.com/products/utility-plants/item/95-ion-exchange</guid>
			<description><![CDATA[<div class="K2FeedIntroText"><p><span style="color: #ffffff;"> List Product</span></p>
</div><div class="K2FeedFullText">
<p> </p>
<div class=" animation fadeInLeft animated visible">
<ul class="tick">
<li><span style="font-family: Calibri, serif;">Strong Acid Cation </span></li>
<li lang="en-US"><span style="font-family: Arial, serif;"><span style="font-size: medium;"><span style="font-family: Calibri, serif;">Weak Acid Cation </span></span></span></li>
<li lang="en-US"><span style="font-family: Arial, serif;"><span style="font-size: medium;"><span style="font-family: Calibri, serif;">Strong Base anion </span></span></span></li>
<li lang="en-US"><span style="font-family: Arial, serif;"><span style="font-size: medium;"><span style="font-family: Calibri, serif;">Weak Base Anion</span></span></span></li>
<li lang="en-US"><span style="font-family: Arial, serif;"><span style="font-size: medium;"><span style="font-family: Calibri, serif;">Mixed Bed </span></span></span></li>
<li lang="en-US"><span style="font-family: Arial, serif;"><span style="font-size: medium;"><span style="font-family: Calibri, serif;">Specialty </span></span></span></li>
<li lang="en-US"><span style="font-family: Arial, serif;"><span style="font-size: medium;"><span style="font-family: Calibri, serif;">Uniform Particle Size </span></span></span></li>
<li lang="en-US"><span style="font-family: Arial, serif;"><span style="font-size: medium;"><span style="font-family: Calibri, serif;">Condensate Polishing</span></span></span></li>
<li lang="en-US"><span style="font-family: Arial, serif;"><span style="font-size: medium;"><span style="font-family: Calibri, serif;">Activated Carbon</span></span></span></li>
<li lang="en-US"><span style="font-family: Arial, serif;"><span style="font-size: medium;"><span style="font-family: Calibri, serif;">Fiberglass Tank</span></span></span></li>
</ul>
</div>
<p> </p>
<p> </p></div>]]></description>
			<author>mellgrafica@gmail.com (Super User)</author>
			<category>Utility Plants</category>
			<pubDate>Thu, 17 Mar 2016 00:00:00 +0000</pubDate>
		</item>
		<item>
			<title>Cooling Water</title>
			<link>http://covalenttrading.com/products/utility-plants/item/96-cooling-water</link>
			<guid isPermaLink="true">http://covalenttrading.com/products/utility-plants/item/96-cooling-water</guid>
			<description><![CDATA[<div class="K2FeedIntroText"><p> </p>
</div><div class="K2FeedFullText">
<p> Cooling Water Systems transfer heat from one substance to another.</p>
<p>Normally, Cooling Water Systems are open to the atmosphere at the tower. As the water recirculates in the Cooling Tower, heat gained by the process is released by evaporation. The cooling water then returns to the heat exchangers to pick up more heat.</p>
<p>Cooling Water System tend to develop problems such as Scale, Fouling and Corrosion. These problems can cause:</p>
<p>It is possible to select the correct Cooling Water program treatment to provide optimum operating conditions for heat exchangers and avoid problems. We offer technical evaluations for these which include:Mechanical, Operational and Chemical evaluations onsite.</p>
<p lang="en-US" align="JUSTIFY"> </p>
<div class=" animation  fadeInLeft animated visible">
<ul class="tick">
<li><span style="font-family: Calibri, serif;">Corrosion Inhibitors</span></li>
<li><span style="font-family: Calibri, serif;">Antiscalants</span></li>
<li><span style="font-family: Calibri, serif;">Salt Dispersants</span></li>
<li><span style="font-family: Calibri, serif;">Non-Oxidant Biocides</span></li>
<li><span style="font-size: medium;"><span style="font-family: Calibri, serif;">Bio-Dispersants</span></span></li>
<li><span style="font-family: Calibri, serif;">Scale Inhibitor and Corrosion Inhibitor</span></li>
<li><span style="font-family: Calibri, serif;">Scale Inhibitors, Corrosion Inhibitor and Biodespersant</span></li>
<li><span style="font-family: Calibri, serif;">Scale Inhibitors</span></li>
<li><span style="font-family: Calibri, serif;">Scale Inhibitors and Corrosion Inhibitor (Zn)</span></li>
<li><span style="font-family: Calibri, serif;">Scale Inhibitors and Biodespersant</span></li>
<li><span style="font-family: Calibri, serif;">Scale Inhibitors and Corrosion Inhibitor</span></li>
</ul>
</div>
<p> </p></div>]]></description>
			<author>mellgrafica@gmail.com (Super User)</author>
			<category>Utility Plants</category>
			<pubDate>Thu, 17 Mar 2016 00:00:00 +0000</pubDate>
		</item>
		<item>
			<title>Steam Boilers</title>
			<link>http://covalenttrading.com/products/utility-plants/item/97-steam-boilers</link>
			<guid isPermaLink="true">http://covalenttrading.com/products/utility-plants/item/97-steam-boilers</guid>
			<description><![CDATA[<div class="K2FeedIntroText"><p> </p>
</div><div class="K2FeedFullText">
<p style="text-align: justify;"> A poor treated steam boiler is a potential high risk in the plant, so getting the correct feed water quality and boiler water chemistry is critical. A complete water treatment program for a steam boiler will usually include an Oxygen scavenger, internal treatment and a condensate piping treatment. A successful water treatment requires:</p>
<p lang="en-US" align="CENTER"> </p>
<div class=" animation  fadeInLeft animated visible">
<ul class="tick">
<li><span lang="en-US">Scale Inhibitor and Internal treatment Corrosion Inhibitor</span></li>
<li><span lang="en-US">Oxygen Scavenger, Scale Inhibitor and Internal treatment Corrosion Inhibitor</span></li>
<li><span lang="en-US">Oxygen Scavenger</span></li>
<li><span lang="en-US">Oxygen Scavenger, Scale Inhibitor, Internal treatment Corrosion Inhibitor and Steam Condensate treatment</span></li>
<li><span lang="en-US">Scale Inhibitor and Internal treatment Corrosion Inhibitor</span></li>
<li><span lang="en-US">Oxygen Scavenger, Scale Inhibitor, Internal Treatment Corrosion Inhibitor (all organic) and Steam Condensate treatment</span></li>
<li><span lang="en-US">Neutralizing amines</span></li>
</ul>
</div>
<p> </p>
<p> </p>
<p> </p></div>]]></description>
			<author>mellgrafica@gmail.com (Super User)</author>
			<category>Utility Plants</category>
			<pubDate>Thu, 17 Mar 2016 00:00:00 +0000</pubDate>
		</item>
	</channel>
</rss>
